HC-K 6/12-EBUS - HC-K 6/12-EBUS 1636363 PHOENIX CONTACT Contact insert
现货 热销产品

HC-K 6/12-EBUS

HC-K 6/12-EBUS 1636363 PHOENIX CONTACT Contact insert

$127.97 美元
库存 114 件
主要规格
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
类型: B16
宽度: 34 mm
高度: 47 mm
供应商信息
产品:0
通常在 2-3 个工作日内发货
质量保证
快速发货
技术支援

技术规格

参数 价值
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
类型 B16
宽度 34 mm
高度 47 mm
长度 84.1 mm
系列 HC-K
一般的 For HEAVYCON ADVANCE and HEAVYCON housing of type B16/B32, axial connection for 2 mm Allen wrench
应用 Power/signal
产品类型 Contact insert with a fixed no. of positions
组装说明 To ensure correct use, installation in housing with IP54 protection or better is required
额定电流 40 A (power contacts)
文章修订 04
接触直径 4 mm
联系材料 Cu alloy
联系电话 1 - 6 (power contacts)
螺丝刀刀片 0.5 x 3.5 mm (control contacts)
拧紧扭矩 2 Nm ... 2.5 Nm (PE connection)
连接配置文件 6+12+PE
污染程度 3
尺寸图
职位数量 18
额定浪涌电压 8 kV (power contacts)
过电压类别 III
连接技术 Axial screw connection (power contacts)
接触材料类型 turned
电源触点数量 6
额定电压(III/3) 690 V
导体横截面 2.5 mm² ... 10 mm² (power contacts)
控制触点数量 12
接触载体材料 PC
插入/拔出周期 ≥ 500
连接横截面 AWG 12 ... 8 (power contacts)
环境温度(运行) -40 °C ... 125 °C
钻孔距离,水平方向 77.5 mm
电源触点的额定电压 230/400 V
根据 UL 94 标准评定的阻燃等级 V0
单根导线的剥线长度 8 mm +1 mm (Power 6 mm² ... 10 mm²)
接触面材料,电源触点 Ag
接触面材料,控制接触 Ag

产品描述

Contact insert, number of poles: 6+12+PE, size: B16, power contacts: 6, control contacts: 12, Female, Axial screw connection, 690 V, 40 A, 2.5 mm² ... 10 mm², application: Power/signal
主要特点
  • 工业级品质
  • 符合RoHS标准
  • CE认证
  • 一年保修

产品文档

数据表

技术规格和性能数据

用户手册

安装和操作指南