| 参数 | 价值 |
|---|---|
| GTIN | 4046356410229 |
| 笔记 | Made to Order (non-returnable) |
| 订单密钥 | 1586277 |
| 产品目录页 | Page 507 (C-2-2017) |
| 包装单元 | 10 pc |
| 原产地 | DE (Germany) |
| 海关关税编号 | 85366990 |
| (关键商业数据) | The axial screw connection must be established using a 2 mm Allen key (for stranded conductors only) |
| 最小订购量 | 10 pc |
| 规模(关键商业数据) | D7 |
| (标准和法规) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| (电气特性) | IEC 60352 |
| 额定电流(材料数据) | 40 A |
| 连接(关键商业数据) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| 额定浪涌电压(材料数据) | 6 kV |
| 单件重量(不含包装) | 23.410 g |
| 接触材料(环境条件) | Copper alloy |
| 额定电压(III/3)(材料数据) | 400 V |
| 中国RoHS(标准和法规) | Environmentally Friendly Use Period = 50 |
| REACH SVHC(标准和法规) | Lead 7439-92-1 |
| 连接方式(关键商业数据) | Axial screw connection |
| 联系电话(关键商业数据) | 1 - 2 |
| 拧紧扭矩(关键商业数据) | 1.8 Nm |
| 环境温度(操作)(一般) | -40 °C ... 125 °C (including heating up of contacts) |
| 污染程度(关键商业数据) | 3 |
| 职位数量(关键商业数据) | 2+PE |
| 过电压类别(关键商业数据) | III |
| 组装说明(关键商业数据) | To ensure correct use, installation in housing with IP54 protection or better is required |
| 导体横截面(关键商业数据) | 4 mm² ... 10 mm² |
| 接触载体材料(环境条件) | PC |
| 接触面材料(环境条件) | Ag |
| 插入/取出周期(关键商业数据) | ≥ 500 |
| 连接横截面 AWG(关键商业数据) | 10 ... 8 |
| 连接符合标准(电气特性) | CUL |
| 单根导线的剥线长度(关键商业数据) | 8 mm +1 |
| 结构和测试规程(电气特性) | DIN VDE 0627/86 |
| 根据 UL 94 标准评定的阻燃等级(电气特性) | V0 |
技术规格和性能数据
安装和操作指南