| 参数 | 价值 |
|---|---|
| GTIN | 4055626620657 |
| 订单密钥 | 1044183 |
| (图纸) | |
| 产品目录页 | Page 50 (C-4-2019) |
| 包装单元 | 1 |
| 注(一般) | The device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area. |
| 深度(图纸) | 65.7 mm (incl. DIN rail 7.5 mm) |
| 宽度(图纸) | 71.2 mm |
| ETIM 5.0 (eCl@ss) | EC000381 |
| ETIM 6.0 (eCl@ss) | EC000381 |
| ETIM 7.0 (eCl@ss) | EC000381 |
| 身高(图纸) | 89.8 mm |
| 海关关税编号 | 85363030 |
| (环境条件) | PBT-FR |
| 海拔(尺寸) | ≤ 3000 m (amsl (above mean sea level)) |
| 类型(环境条件) | DIN rail module, two-section, divisible |
| (补充说明) | ≤ 700 µA AC |
| 颜色(环境条件) | jet black RAL 9005 |
| 水平螺距(图纸) | 4 Div. |
| (标准和法规) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| EN 型(环境条件) | T1 / T2 |
| eCl@ss 4.0(分类) | 27130800 |
| eCl@ss 4.1(分类) | 27130800 |
| eCl@ss 5.0(分类) | 27130800 |
| eCl@ss 5.1(分类) | 27130800 |
| eCl@ss 6.0(分类) | 27130800 |
| eCl@ss 7.0(分类) | 27130802 |
| eCl@ss 8.0(分类) | 27130802 |
| eCl@ss 9.0(分类) | 27130802 |
| 尺寸图(图纸) | |
| 冲击(操作)(尺寸) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| 防护等级(尺寸) | IP20 (only when all terminal points are used) |
| 无障碍环境(环境条件) | Accessible |
| 安装类型(环境条件) | DIN rail: 35 mm |
| 振动(操作)(尺寸) | 5g (5-500 Hz/2.5 h/XYZ) |
| 房屋材料(环境条件) | PA 6.6-FR |
| 中国RoHS(标准和法规) | Environmentally Friendly Use Period = 50 |
| REACH SVHC(标准和法规) | Lead 7439-92-1 |
| 保护模式(环境条件) | (DC+) - (DC-) |
| 标准/法规(连接数据) | EN 50539-11 2013 |
| 污染程度(环境条件) | 2 |
| SPD失效行为(环境条件) | OCM (Open-circuit mode) |
| (保护电路直流电压侧(DC)) | 4.5 Nm (25 mm² ... 35 mm²) |
| 安装位置(环境条件) | Interior |
| 响应时间 tA(附加说明) | ≤ 25 ns |
| 环境温度(操作)(尺寸) | -40 °C ... 85 °C |
| IEC测试分类(环境条件) | PV I / II |
| 连接配置(环境条件) | Y configuration |
| 允许湿度(运行)(尺寸) | 5 % ... 95 % |
| 剩余电流IPE(附加说明) | ≤ 40 µA DC |
| 额定负载电流 IL(附加说明) | 80 A |
| 浪涌保护故障信息(环境条件) | optical |
| 环境温度(储存/运输)(尺寸) | -40 °C ... 85 °C |
| 绝缘电阻 Riso(附加说明) | > 5 GΩ (at 500 V DC) |
| 螺纹(保护电路直流电压侧(DC)) | M5 |
| PC待机功耗(附加说明) | ≤ 25 mVA |
| 剥线长度(保护电路直流电压侧(DC)) | 16 mm |
| 连接方式(保护电路直流电压侧(DC)) | Fork-type cable lug |
| 连续工作电流 ICPV(附加说明) | < 20 µA |
| 根据 UL 94 标准(环境条件)评定的阻燃等级 | V-0 |
| 拧紧扭矩(保护电路直流电压侧(DC)) | 3 Nm (1.5 mm² ... 16 mm²) |
| 短路电流额定值 ISCPV(附加说明) | 2000 A |
| 带电部件与接地部件之间的距离(环境条件) | 8 mm |
| 标称放电电流 (8/20) µs(附加说明) | 15 kA |
| 最大放电电流 Imax(8/20) µs(附加说明) | 40 kA |
| 断开装置的安装位置(环境条件) | Internal |
| 最大连续工作电压 UCPV(附加说明) | 1170 V DC |
| 总放电电流 Itotal(8/20) µs(附加说明) | 40 kA |
| 导线横截面 AWG(保护电路直流电压侧 (DC)) | 15 ... 2 |
| 总放电电流 Itotal(10/350) µs(附加说明) | 10 kA |
| 导体横截面实心(保护电路直流电压侧(DC)) | 1.5 mm² ... 35 mm² |
| 脉冲放电电流 (10/350) µs,电荷(附加说明) | 2.5 As |
| 导体横截面柔性(保护电路直流电压侧(DC)) | 1.5 mm² ... 16 mm² |
| 脉冲放电电流 (10/350) µs,峰值极限(附加说明) | 5 kA |
| 脉冲放电电流(10/350)µs,比能量(附加说明) | 6.25 kJ/Ω |
技术规格和性能数据