| 参数 | 价值 |
|---|---|
| GTIN | 4017918876845 |
| 订单密钥 | 2856582 |
| 产品目录页 | Page 54 (C-4-2017) |
| 包装单元 | 1 pc |
| 注(一般) | Usable in all low-voltage systems between L-N or L-PEN.Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE= RAaccordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a) |
| 原产地 | DE (Germany) |
| 海关关税编号 | 85363030 |
| (环境条件) | PBT |
| (保护电路) | 4.5 Nm (25 mm² ... 35 mm²) |
| (UL连接数据) | EN 61643-11 2012 |
| 海拔(尺寸) | ≤ 2000 m (amsl (above mean sea level)) |
| 类型(环境条件) | DIN rail module, two-section, divisible |
| (补充说明) | 440 V AC (120 min / withstand mode) |
| 颜色(环境条件) | jet black RAL 9005 |
| SPD 类型(连接数据) | 4CA |
| 深度(关键商业数据) | 65.7 mm (incl. DIN rail 7.5 mm) |
| 宽度(关键商业数据) | 17.6 mm |
| (标准和法规) | No hazardous substances above threshold values |
| EN 型(环境条件) | T2 |
| 高度(关键商业数据) | 89.8 mm |
| 额定电压(连接数据) | 240 V AC |
| 冲击(操作)(尺寸) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| 防护等级(尺寸) | IP20 (only when all terminal points are used) |
| 螺纹(保护电路) | M5 |
| 安装类型(环境条件) | DIN rail: 35 mm |
| 振动(操作)(尺寸) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| 标称频率(连接数据) | 50/60 Hz |
| 保护模式(连接数据) | L-N |
| 单件重量(不含包装) | 110.030 g |
| 房屋材料(环境条件) | PA 6.6 |
| 剥线长度(保护电路) | 16 mm |
| 拧紧扭矩(UL 规范) | 30 lbf-in. |
| 中国RoHS(标准和法规) | Environmentally friendly use period: unlimited = EFUP-e |
| 连接方式(保护电路) | Fork-type cable lug |
| 水平螺距(关键商业数据) | 1 Div. |
| 拧紧扭矩(保护电路) | 3 Nm (1,5 mm² ... 16 mm²) |
| 保护模式(环境条件) | L-N |
| 污染程度(环境条件) | 2 |
| 位置数量(环境条件) | 1 |
| 响应时间 tA(附加说明) | ≤ 100 ns |
| 标准/法规(UL连接数据) | IEC 61643-11 2011 |
| 配电系统(连接数据) | Single phase |
| 环境温度(操作)(尺寸) | -40 °C ... 80 °C |
| IEC电源系统(环境条件) | TN |
| IEC测试分类(环境条件) | II |
| 额定电压 UN(附加说明) | 240/415 V AC (TN) |
| UT 下的 TOV 行为(补充说明) | 415 V AC (5 s / withstand mode) |
| 允许湿度(运行)(尺寸) | 5 % ... 95 % |
| 标称频率 fN(附加说明) | 50 Hz (60 Hz) |
| 剩余电流IPE(附加说明) | ≤ 5 µA |
| 导线横截面 AWG(UL 规范) | 10 ... 2 |
| 额定负载电流 IL(附加说明) | 80 A |
| 残余电压(附加说明) | ≤ 1.2 kV (at In) |
| 导线横截面 AWG(保护电路) | 15 ... 2 |
| 导体横截面实心(保护电路) | 1.5 mm² ... 35 mm² |
| 标称放电电流 In(LN)(连接数据) | 10 kA |
| 浪涌保护故障信息(环境条件) | optical |
| 环境温度(储存/运输)(尺寸) | -40 °C ... 80 °C |
| 导体横截面柔性(保护电路) | 1.5 mm² ... 16 mm² |
| 测得的极限电压 MLV (LN)(连接数据) | 2420 V |
| 电压保护等级提升(附加说明) | ≤ 1.5 kV |
| PC待机功耗(附加说明) | ≤ 2 mVA |
| 最大连续电压 UC(附加说明) | 350 V AC |
| 根据 UL 94 标准(环境条件)评定的阻燃等级 | V-0 |
| 短路电流额定值 ISCCR(附加说明) | 25 kA |
| 带分支线路的最大备用保险丝(附加说明) | 125 A (gG) |
| 标称放电电流 In(8/20) µs(附加说明) | 10 kA |
| 最大连续工作电压 MCOV (LN)(连接数据) | 350 V AC |
| 最大放电电流 Imax(8/20) µs(附加说明) | 20 kA |
| 最大备用保险丝,V型直通接线(附加说明) | 80 A (gG) |
| 波前击穿电压在 6 kV (1.2/50) µs 时(附加说明) | ≤ 1.5 kV |
技术规格和性能数据
安装和操作指南