| 参数 | 价值 |
|---|---|
| Ue | |
| 华盛顿特区 | Resistive load (DC-12) |
| IE | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| 物品 | Specifications |
| 电缆 | UL style 2464, No.22 AWG 12-core |
| 重量 | Approx. 600 g |
| 细节 | Magnet lock type |
| 产品 | Ultra-slim Safety door switch with solenoid interlock |
| 材料 | Enclosure : PA66 |
| 保护 | IP 67 (IEC 60529) |
| 零件编号 | SG-B1-MB-G5 |
| 电缆长度 | 5m16.404 ft |
| 产品名称 | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| 主要联系人 | 1NC + 1NC |
| 产品编号 | SG-B1-MB-G5 |
| 互锁力 | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| 抗冲击性 | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| 接触电阻 | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| 工作频率 | 900 operations/hour |
| 适用标准 | EN 60947-5-1, GS-ET-19 |
| 直接开启力 | 60 N min. |
| 门禁监控电路 | AC |
| 抗振性能 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| 直接开启旅行 | 8 mm0.315 inmin. |
| 门监控触点 | 2NC |
| 电气耐久性 | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| 锁定监视器触点 | 1NO |
| 机械耐久性 | 1,000,000 operations min. (GS-ET-19) |
| 热电流(Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| 适用法规 | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| 感性负载(AC-15) | - |
| 感性负载(DC-13) | 1A |
| 执行器运行速度 | 0.05 to 1.0 m/sec. |
| 额定绝缘电压(Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| 运行条件:海拔 | 2,000 m6,561.68 ftmax. |
| 电击防护等级 | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| 短路保护装置 | Use 250 V / 10 A fast acting type fuse |
| 冲击耐受电压(Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| 电磁阀/指示器:指示器 | Green LED |
| 电磁阀/指示器:额定电流 | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| 工作条件:环境湿度 | 45 to 85 % RH |
| 运行条件:污染程度 | 3 (Inside 2) |
| 电磁阀/指示灯:开启电压 | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| 电磁阀/指示灯:关闭电压 | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| 适用标准:使用标准 | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| 工作条件:环境温度 | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| 电磁阀/指示器:额定工作电压 | DC 24 V 100% duty cycle |
| 额定工作电压 (Ue) / 额定工作电流 (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |