| 参数 | 价值 |
|---|---|
| When communication unitis connected | |
| 物品 | Specifications |
| 电缆 | 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| 细节 | Slave unit / High performance type |
| 产品 | Controller |
| 材料 | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| 净重 | 140 g approx. |
| 零件编号 | HG-TC111-P |
| 1至7个单位 | 1 to 6 units |
| 产品名称 | Thru-beam Type Digital Displacement Sensor HG-T |
| 8至15个单位 | 7 to 14 units |
| 显示范围 | -199.999 to 199.999 mm-7.874 to 7.874 in |
| 采样率 | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| 产品编号 | HG-TC111-P |
| 供电电压 | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| 污染程度 | 2 |
| 显示分辨率 | 1 μm0.039 mil |
| 运行高度 | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| 当前消耗 | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| 监管合规 | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| 适用传感器头 | HG-T1010、HG-T1110 |
| 外部输入切换 | Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop". |
| 外部输出切换 | Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. |
| 平均计数(响应时间) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| 连接的从属单元数量 | Maximum sink current and sourcecurrent of control output |
| 环境抵抗力:保护 | IP40(IEC) |
| 模拟输出:模拟电流输出 | •Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| 模拟输出:模拟电压输出 | •Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| 外部输入(输入 1、输入 2、输入 3) | Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx. |
| 可连接控制器的最大数量 | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| 环境耐受性:环境湿度 | 35 to 85 % RH, Storage: 35 to 85 % RH |
| 环境耐受性:抗冲击性 | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| 控制输出(输出 1、输出 2、输出 3) | NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| 环境耐受性:环境温度 | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| 环境耐受性:抗振性 | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| 环境耐受性:绝缘阻力 | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| 环境耐受性:耐压能力 | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
| 外部输入(输入 1、输入 2、输入 3):输入时间 | • Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| 控制输出(输出 1、输出 2、输出 3):报警输出 | Open when alarm occurs |
| 控制输出(输出 1、输出 2、输出 3):判断输出 | N.O. / N.C. switching type |
| 控制输出(输出 1、输出 2、输出 3):短路保护 | Incorporated (automatic reset type) |