| 参数 | 价值 |
|---|---|
| typ. 92 % (240 V AC) | |
| 深度 | 160 mm |
| 输入 | 4 kV |
| 震惊 | 30g, 18 ms in accordance with IEC 60068-2-27 |
| 宽度 | 88 mm |
| 死板的 | 1 mm² ... 4 mm² |
| 高度 | 130 mm |
| 输出 | 2 kV |
| 信号 | 2 kV |
| 锁定 | Screw |
| 电压 | 10 V |
| 降息 | > 60 °C (2.5%/K of POutnom.) |
| 灵活的 | 1 mm² ... 2.5 mm² |
| 界面 | USB (Modbus/RTU) |
| 上升时间 | < 34 ms |
| EN 61010-1 | II |
| 效率 | typ. 88 % (100 V AC) |
| 输入保险丝 | 10 A (slow-blow, internal) |
| 低信号 | Connection to SGnd with < 2.7 kΩ |
| 高信号 | Open (> 200 kΩ between Bat.-Start and SGnd) |
| 刚性(AWG) | 16 ... 12 |
| 佳洁士因子 | 1.57 (120 V AC) |
| 引擎盖版 | PC |
| 产品类型 | DC UPS with integrated power supply |
| 安装类型 | DIN rail mounting |
| 气候等级 | 3K3 (in acc. with EN 60721) |
| 鉴别 | UL Listed UL 61010 |
| 浪涌电流 | < 10 A |
| 噪声排放 | EN 61000-6-3 |
| 抗噪声能力 | Immunity in accordance with EN 61000-6-2 (industrial) |
| 输出电压 | 24 V DC |
| 产品系列 | TRIO UPS |
| 开机时间 | typ. 200 ms |
| 频率范围 | 80 MHz ... 6 GHz |
| 残余涟漪 | < 20 mV |
| 空气排放 | 8 kV (Test Level 3) |
| 最大海拔 | ≤ 4000 m (> 2000 m, observe derating) |
| 阶段数 | 1.00 |
| 保护等级 | I |
| 剥皮长度 | 10 mm |
| 切换时间 | < 3 ms |
| 切换输出 | Transistor output, active |
| 连接方式 | Push-in connection |
| 接触放电 | 6 kV (Test Level 3) |
| 控制偏差 | < 0.4 % (change in load, static 10 % ... 90 %) |
| 安装位置 | horizontal DIN rail NS 35, EN 60715 |
| 输出电流 IN | 20 A |
| 信号类型 | LED red |
| 电池技术 | VRLA-AGM |
| 标称电压 UN | 24 V DC |
| 充电电流() | 3 A |
| 连接标签 | 3.6 |
| 污染程度 | 2 |
| 输入电压范围 | 100 V AC ... 240 V AC -15 % ... +10 % |
| 测试场强 | 10 V/m |
| 保护程度 | IP20 |
| 频率范围(fN) | 50 Hz ... 60 Hz (±10 %) |
| LED状态指示灯 | red |
| 主电源缓冲时间 | ≥ 20 ms (120 V AC) |
| 接口数量 | 1 |
| 输出电压范围 | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| 侧元素版本 | Aluminum |
| 标准名称 | Safety for equipment for measurement, control, and laboratory use |
| 组装说明 | alignable: horizontally 0 mm, vertically 50 mm |
| 充电结束电压 | max. 30 V DC |
| 低电压指令 | Conformance with Low Voltage Directive 2014/35/EC |
| 标准/法规 | EN 61000-3-2 |
| 振动(操作) | in accordance with IEC 60068-2-6 |
| 标称容量范围 | 4 Ah ... 40 Ah |
| 连续负载电流 | 20 mA |
| 允许的备用保险丝 | B16 |
| 传导噪声发射 | EN 61000-6-3 |
| 标准/规范 | IEC 61010-1 |
| UPS串联连接 | no |
| 充电电流(预设) | 2.1 A (-25 °C ... 40 °C) |
| 信号标识 | Bat.-Start |
| 充电电流(降低) | 3 A ... 0 A (40 °C ... 65 °C) |
| 动态加速(IDyn.Boost) | 30 A |
| 平均故障间隔时间 (IEC 61709,SN 29500) | 958219 h (25 °C) |
| UPS并联连接 | yes, with diode module uncoupled |
| 电荷特性曲线 | IU0U |
| 反馈电压电阻 | ≤ 35 V DC |
| 典型电流消耗 | 6.4 A (100 V AC) |
| 额定负载最大功率损耗 | < 50 W (230 V AC) |
| 电磁兼容性 | Conformance with EMC Directive 2014/30/EU |
| 浪涌电流积分 (I2t) | < 0.4 A2s |
| 供电电压类型 | AC |
| 环境温度(运行) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| 充电电流(可配置) | 0.2 A ... 3 A (-25 °C ... 40 °C) |
| 安装距离(右/左) | 0 mm / 0 mm |
| 安装距离(顶部/底部) | 50 mm / 50 mm |
| 最大空载功耗 | < 4 W (230 V AC) |
| 噪声发射的电磁兼容性要求 | EN 61000-6-3 |
| 抗噪声能力的电磁兼容性要求 | EN 61000-6-1 |
| 环境温度(储存/运输) | -40 °C ... 85 °C |
| 柔性带套圈和塑料套管 | 1 mm² ... 1.5 mm² |
| 环境温度(启动类型测试) | -40 °C |
| 储能装置并联连接 | yes |
| 柔性带套圈,无塑料套管 | 1 mm² ... 2.5 mm² |
| 最大允许相对湿度(运行) | ≤ 95 % (At +25°C, non-condensing) |
| 输出过压保护 (OVP) | < 30 V DC |
| 根据 UL 94 标准评定的阻燃等级(外壳/接线端子) | V0 |
技术规格和性能数据
安装和操作指南