| 参数 | 价值 |
|---|---|
| 25 min. (2 A) | |
| 深度 | 61 mm |
| 输入/输出 | asymmetrical |
| 输入 | 2 kV (Test Level 3 - asymmetrical) |
| 震惊 | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| 宽度 | 108 mm |
| 高度 | 90 mm |
| 输出 | 2 kV (Test Level 3 - asymmetrical) |
| 信号 | 2 kV (Test Level 4 - asymmetrical) |
| 电压 | 10 V (Test Level 3) |
| 评论 | Criterion A |
| 降息 | 35 °C ... 40 °C (5 %/K) |
| 效率 | > 98 % (Mains operation, with charged energy storage) |
| 输入保险丝 | 7 A (slow-blow, internal) |
| 标准 A | Normal operating behavior within the specified limits. |
| 标准 B | Temporary impairment to operational behavior that is corrected by the device itself. |
| 输出功率 | 72 W |
| 产品类型 | DC UPS |
| 螺纹 | M3 |
| UL认证 | UL Listed UL 508 |
| 组装说明 | alignable: horizontally 0 mm, vertically 50 mm |
| 过渡时间 | 900 s |
| 缓冲期 | 50 min. (1 A) |
| IQ技术 | no |
| 输入电压 | 24 V DC |
| 存储介质 | Lithium polymer |
| 安装类型 | DIN rail mounting |
| 气候等级 | 3K3 (in acc. with EN 60721) |
| 状态显示 | LED |
| 频率范围 | 80 MHz ... 1 GHz |
| 住房类型 | Plastic |
| 文章修订 | 03 |
| 充电电流 | 0.4 A |
| 空气排放 | 8 kV (Test Level 3) |
| 房屋材料 | Polycarbonate |
| 额定容量 | 1.4 Ah |
| 保护等级 | III |
| 剥皮长度 | 6.5 mm |
| 连接方式 | Screw connection |
| 接触放电 | 6 kV (Test Level 3) |
| 安装位置 | horizontal DIN rail NS 35, EN 60715 |
| 功率损耗 | 0.6 W (Mains operation) |
| 电池技术 | LIPO |
| 网管 | No |
| 标称电压 UN | 18.5 V DC |
| 输出描述 | Transistor |
| 信号类型 | LED |
| 当前消耗 | 4.7 A |
| 污染程度 | 2 |
| 脚闩材料 | POM (Polyoxymethylene) |
| 输入电压范围 | 22.5 V DC ... 29.5 V DC |
| 输出电流 Imax | 4 A (0 °C ... 35 °C) |
| 测试场强 | 10 V/m (Test Level 3) |
| 串联连接 | no |
| 保护程度 | IP20 |
| 输出电流限制 | In mains mode according to connected upstream current limiting device |
| 输出电压范围 | 22.5 V DC ... 29.5 V DC (UOut= UIn- 0.3 V DC) |
| 动力提升(iBoost) | 4 A (0 °C ... 35 °C) |
| 充电结束电压 | 18.5 V DC ... 21 V DC |
| 标准/法规 | EN 61000-4-2 |
| 最大拧紧扭矩 | 0.8 Nm |
| 典型响应时间 | < 0.5 s |
| 振动(操作) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 固定备份阈值 | < 22.5 V |
| 标称容量范围 | 1.4 Ah |
| 标称输出电压 | 24 V DC |
| 状态显示说明 | static on |
| 旋转选择开关 | Service |
| 拧紧扭矩,最小 | 0.6 Nm |
| 电池质量检查 | yes, with each charge and cyclically once per month |
| 深度放电保护 | < 15 V DC |
| 信号标识 | Power In OK |
| 平均故障间隔时间 (IEC 61709,SN 29500) | > 1401000 h (40 °C) |
| 可变连接阈值 | 1 V / 1 s |
| 标称输入电压范围 | 24 V DC |
| 额定输出电流(IN) | 3 A (0 °C ... 40 °C) |
| 标准 - 电气安全 | EN 60950-1/VDE 0805 (SELV) |
| 电磁兼容性 | Conformance with EMC Directive 2014/30/EU |
| 供电电压类型 | DC |
| 环境温度(运行) | 0 °C ... 40 °C |
| 电池存在检查(循环) | 60 s |
| 导体横截面 AWG 最大值 | 12 |
| 导体横截面 AWG 最小值 | 24 |
| 安装距离(右/左) | 0 mm / 0 mm |
| 安装距离(顶部/底部) | 0 mm / 0 mm |
| 导体横截面,刚性最大值 | 2.5 mm² |
| 导体横截面,刚性最小。 | 0.2 mm² |
| 噪声发射的电磁兼容性要求 | EN 61000-6-3 |
| 抗噪声能力的电磁兼容性要求 | EN 61000-6-1 |
| 导体横截面柔性最大值。 | 2.5 mm² |
| 导体横截面柔性最小。 | 0.2 mm² |
| 环境温度(储存/运输) | -20 °C ... 45 °C |
| 最大允许相对湿度(运行) | ≤ 95 % (at 25 °C, non-condensing) |
| 发射的无线电干扰符合 EN 55011 标准 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| 符合 EN 55011 标准的无线电干扰电压 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| 标准——用于电力装置的电子设备及其在电力装置中的组装 | EN 50178/VDE 0160 (PELV) |
技术规格和性能数据
安装和操作指南