| 参数 | 价值 |
|---|---|
| 134 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| MTTF | 293 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| 深度 | 115 mm |
| 输入 | ± 2.2 kV |
| 宽度 | 23 mm |
| 高度 | ≤ 2000 m |
| 信号 | Ethernet |
| 电压 | 10 V |
| 评论 | Criterion B |
| 材料 | PA 6.6-FR |
| 电源型 | Permanent line |
| 证书 | CE-compliant |
| 标准 A | Normal operating behavior within the specified limits. |
| 标准 B | Temporary impairment to operational behavior that is corrected by the device itself. |
| 输出功率 | ≤ 91 W (With PoL) |
| 产品类型 | Ethernet extenders |
| 安装类型 | DIN rail mounting |
| 鉴别 | ISA-S71.04-1985 G3 Harsh Group A |
| 噪声排放 | EN 61000-6-4, Class A, industrial area of application |
| 抗噪声能力 | EN 55035 |
| 基本功能 | Gigabit Ethernet extender in accordance with ITU G.9960 |
| 场强 | 10 V/m |
| 频率范围 | 80 MHz ... 3 GHz (80% amplitude modulation with 1 kHz) |
| 频道数量 | 1 |
| 空气排放 | ± 8 kV |
| 污染程度 | 2 |
| 剥皮长度 | 10 mm |
| 连接方式 | Push-in spring connection |
| 接触放电 | ± 6 kV |
| 横截面AWG | (converted acc. to IEC) |
| 安装位置 | Vertical (horizontal DIN rail) |
| 功耗 | ≤ 7.5 W (Without PoL, without PoE) |
| 间接排放 | ± 6 kV |
| 保护电路 | Overload protection, protection against polarity reversal; Internal device protection: 2x 5 AF, internal series diode |
| 传动速度 | ≤ 1000 Mbps (Depending on the quality of the data line) |
| 尺寸图 | |
| 支持的协议 | Protocol-transparent for TCP/IP, IPv4, and IPv6 |
| 传输长度 | < 100 m (shielded twisted pair) |
| 传输方法 | QAM (quadrature amplitude modulation) carrier frequency method |
| 保护程度 | IP20 |
| 电气隔离 | VCC (US+GND) // Ethernet (PoE) // G.hn (without PoL) // FE |
| 最大输出功率 | 15 W (at ≤55°C) |
| 供电电压范围 | 18 V DC ... 57 V DC |
| 组装说明 | To allow for air circulation, mount the device freestanding, with a clearance of at least one centimeter on all sides to other devices. |
| 标准/法规 | EN 61000-4-2 |
| 标称供电电压 | 24 V DC (Without PoL, without PoE) |
| 串行传输速度 | 10/100/1000 Mbps |
| 电磁兼容性 | Conformance with EMC Directive 2014/30/EU |
| 环境温度(运行) | -40 °C ... 60 °C (Free standing, without PoE) |
| 允许湿度(运行) | 10 % ... 95 % (non-condensing) |
| 单线/接线端子,柔性 | 0.2 mm² ... 2.5 mm² |
| 根据 UL 94 标准评定的阻燃等级 | V0 |
| 单导体/接线端子,刚性 | 0.2 mm² ... 2.5 mm² |
| 环境温度(储存/运输) | -40 °C ... 85 °C |
| 柔性导体横截面 [AWG] | 24 ... 16 |
| 允许湿度(储存/运输) | 10 % ... 95 % (non-condensing) |
| 测试电压数据接口/电源 | 1.5 kV AC (50 Hz, 1 min.) |
| 导体横截面,柔性,带套圈,带塑料套管 | 0.2 mm² ... 2.5 mm² |
| 导体横截面柔性,带套圈,无塑料套管 | 0.2 mm² ... 2.5 mm² |
| 两根横截面相同的柔性导线,带双套管。 | 0.5 mm² ... 1.5 mm² |