| 参数 | 价值 |
|---|---|
| GTIN | 4046356690676 |
| 订单密钥 | 2800918 |
| (一般的) | > 17 V (typ. ON) |
| 产品目录页 | Page 323 (C-4-2017) |
| 包装单元 | 1 pc |
| 原产地 | DE (Germany) |
| (电气数据) | EMV EN 61000-6-2 Noise immunity |
| 保险丝类型(通用) | electronic |
| 海关关税编号 | 85362010 |
| 电压降(一般) | 100 mV (at IN) |
| 绊倒方法(通用) | E (electronic) |
| 类型(环境条件) | Male |
| 颜色(环境条件) | gray |
| 湿度测试(尺寸) | 96 h, 95 % RH, 40 °C |
| 深度(关键商业数据) | 52 mm |
| 工作电压(一般) | 24 V DC |
| 功率损耗(一般) | 0.81 W (Nominal operation) |
| 宽度(关键商业数据) | 12.3 mm |
| (标准和法规) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| 高度(关键商业数据) | 45 mm |
| 额定电流 IN(一般) | 4 A |
| 介电强度(一般) | max. 30 V DC (Load circuit) |
| 额定浪涌电压(一般) | 0.5 kV |
| 所需备用保险丝(通用) | not required, integrated failsafe element |
| 温度降额(一般) | 4 A (at 50 °C) |
| 防护等级(尺寸) | IP30 (Actuation area) |
| 安装类型(环境条件) | on base element |
| 振动(操作)(尺寸) | 3g (In accordance with IEC 60068-2-6, Test Fc) |
| 主动电流限制(通用) | typ. 1.25 x IN |
| 辅助接触类型(一般) | floating signal contact |
| 闭合电路电流 I0(通用) | typ. 8 mA (When switched on) |
| 停机时间负载电路(通用) | 200 ms (see time/current characteristic curve) |
| 单件重量(不含包装) | 35.900 g |
| 中国RoHS(标准和法规) | Environmentally Friendly Use Period = 50 |
| 污染程度(环境条件) | 2 |
| 位置数量(环境条件) | 1 |
| 标准/规范(电气数据) | UL 2367 UL recognized |
| 完整模块深度(关键商业数据) | 77.3 mm |
| 完整模块宽度(关键商业数据) | 12.3 mm |
| 最大容性负载电路(通用) | 20000 µF |
| 环境温度(操作)(尺寸) | -25 °C ... 50 °C (non-condensing) |
| 完整模块高度(关键商业数据) | 90 mm |
| 欠压关断负载电路(通用) | < 14 V (typ. OFF) |
| 安装说明(环境条件) | When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted. |
| 环境温度(储存/运输)(尺寸) | -40 °C ... 70 °C |
| 最大辅助触点工作电流(通用) | 0.5 A |
| 辅助触点最大工作电压(通用) | 30 V DC |
| 最小辅助触点工作电流(通用) | 10 mA |
| 最小辅助触点工作电压(通用) | 10 V DC |
| 根据 UL 94 标准(环境条件)评定的阻燃等级 | V0 |
技术规格和性能数据