| 参数 | 价值 |
|---|---|
| (400 V AC) 100 kA | |
| ETIM 4 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 5 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 6 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| 联合国特别委员会 | 39121601 |
| eClass | V11.0 : 27370409 |
| 标准 | IEC/EN 60947-1 |
| 功率损失 | at Rated Operating Conditions per Pole 0.6 ... 1.6 W |
| RoHS状态 | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| 特征名称 | Feature Value |
| 执行器类型 | Rotary Handle |
| 设置范围 | 1.6 ... 2.5 A |
| 终端类型 | Screw Terminals |
| WEEE类别 | 5. Small Equipment (No External Dimension More Than 50 cm) |
| CB证书 | 1SAA963002-2002 |
| KC证书 | 1SAA963002-1502 |
| UL认证 | E137861-20090225 |
| WEEE B2C / B2B | Business To Business |
| CCC证书 | 2020980307003526 |
| CQC证书 | CQC2010010307387700 |
| 杆数 | 3 |
| 污染程度 | 3 |
| RMRS证书 | 1SAA918000-0704 |
| RoHS 信息 | 1SAA963006-4502 |
| 尺寸图 | 1SAM300402F0001 |
| 锁止转子电流 | (120 V AC) Single Phase 15 A |
| 安装位置 | 1 ... 6 |
| 产品净宽 | 45 mm |
| REACH声明 | 1SAA963005-4502 |
| 拧紧扭矩 | Main Circuit 0.8 ... 1.2 N·m |
| E编号(芬兰) | 3707274 |
| 产品净高 | 90 mm |
| 产品净重 | 0.265 kg |
| I²t 特性 | 1SAM300517F0001 |
| 一级包装 EAN | 4013614484971 |
| 二级包装 EAN | 4013614487170 |
| 额定频率 (f) | Main Circuit 50 Hz |
| 保护程度 | Housing IP20 |
| 安装在 DIN 导轨上 | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| 海关税则号 | 85362010 |
| 电气耐久性 | 50000 cycle |
| 机械耐久性 | 100000 cycle |
| 一级包装单元 | box 1 piece |
| 包装层 1 宽度 | 92 mm |
| 二级包装单元 | carton 40 piece |
| 包装层 2 宽度 | 280 mm |
| 剥线长度 | Main Circuit 9 mm |
| 最低订购量 | 1 piece |
| 包装层 1 高度 | 50 mm |
| 包装层 2 高度 | 210 mm |
| A2L认证 – IEC | 1SAA963000-4601 |
| 环境空气温度 | Around the Enclosure 0 ... +40 °C |
| CAD尺寸图 | 2CDC001079B0201 |
| 临终关怀指示 | 1SAC200332H0001 |
| 满载电流电机使用 | (120 V AC) Single Phase 2.5 A |
| 马力等级 UL/CSA | (220 ... 240 V AC) Single Phase 0.17 Hp |
| 说明书和手册 | 2CDC131057M6801 |
| 额定电压(EF003977) | 690 V |
| 推荐使用的螺丝刀 | M3.5 |
| 抗振性能 | 5g 3 ... 150 Hz |
| 拧紧扭矩 UL/CSA | Main Circuit 10 ... 12 in·lb |
| 最小安装距离 | Electrical Conductive Board, Vertical 75 mm |
| 工作频率(fsw) | 0 ... 400 Hz |
| 额定工作电压 | Main Circuit 690 V AC |
| 杆数(EF001391) | 3 |
| 对象分类代码 | F |
| 产品净深/长度 | 86.75 mm |
| 接触位置指示 | ON / OFF / TRIP |
| 一级包裹毛重 | 0.28 kg |
| 二级包装毛重 | 11.586 kg |
| 额定绝缘电压 (Ui) | 690 V |
| 符合性声明 - CE | 1SAD101100-3404 |
| 设备构造(EF008240) | Complete device in housing |
| 包装层 1 深度/长度 | 95 mm |
| 包装层 2 深度/长度 | 395 mm |
| 额定工作电流 (Ie) | 2.5 A |
| 符合性声明 - CCC | 2020980307003526 |
| 电机驱动可选(EF007386) | No |
| 连接容量主电路 | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| 符合性声明 - UKCA | 1SAD201100-3404 |
| UL/CSA 最大工作电压 | Main Circuit 600 V AC |
| 数据表,技术信息 | 2CDC131058D0201 |
| 说明书和手册(第二部分) | 2CDC131060M0202 |
| 电机驱动集成(EF006697) | No |
| 时域电流特性曲线 | 1SAM300535F0007 |
| IDEA 粒度类别代码 (IGCC) | 4864 >> Enclosed 3 Pole Circuit Breakers |
| 控制元件类型(EF006976) | Rotating button |
| 短路电流额定值 (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA |
| 《有毒物质控制法》(TSCA) | 2CMT2023-006539 |
| 环境空气温度补偿 | Yes |
| 保护等级 (IP) (EF005474) | IP20 |
| 额定永电流 Iu (EF001389) | 2.5 A |
| 最大允许运行高度 | 2000 m |
| 额定冲击耐受电压 (Uimp) | Main Circuit 6 kV |
| 带关闭指示灯 (EF007006) | Yes |
| 主电路连接容量符合UL/CSA标准 | Flexible 1/2x 16-12 AWG |
| 抗冲击性能符合IEC 60068-2-27标准 | 11 ms Pulse 25g |
| 冲突矿产报告模板(CMRT) | 9AKK108467A5658 |
| 传统自由空气热流 (Ith) | Main Circuit 2.5 A |
| 过载释放电流设定值(EF002336) | 1.6 A |
| 集成接地故障保护(EF007296) | No |
| 带保护单元的完整设备(EF008906) | Yes |
| 额定工作短路分断能力 (Ics) | (230 V AC) 100 kA |
| DIN导轨(顶帽导轨)安装可选(EF008904) | Yes |
| 额定极限短路分断能力 (Icu) | (400 V AC) 100 kA |
| 额定瞬时短路电流设定值(II) | 50 A |
| 适用于DIN导轨(顶帽导轨)安装(EF007250) | Yes |
| 主电路的电气连接类型(EF006819) | Screw connection |
| 主电流回路连接位置(EF006671) | Front |
| 调整范围无延迟短路释放(EF007131) | 50 A |
| 辅助触点数量(用作转换触点)(EF003531) | 0 |
| 辅助触点数量(常开触点)(EF001376) | 0 |
| 辅助触点数量(常闭触点)(EF001377) | 0 |
| 额定短路分断能力 Icu(400 V,50 Hz)(EF007048) | 100 kA |
技术规格和性能数据
安装和操作指南